                                      LOW-FUME AND NON-HALOGEN FIRE-RETARDANT WIRES
                                      Series : LOSH flame retardant Cable
                                      keywords : Ev cable; Solar cable; Building Cable; UL Approved Electronic Hook-up Wire|LOSH flame retardant Cable|LOW-FUME AND NON-HALOGEN FIRE-RETARDANT WIRES
                                      Description : Applicable scopeThese products are suitable to be ...
                                      021-57186991
                                      Description
                                      Parameters
                                      Description

                                      Applicable scope

                                      These products are suitable to be installed in those places requiring,non-halogen,low-fume and flame-retardance. 


                                      Production scope

                                      Power cable with rated voltage up to and including 26/35kV, Control Cable and Instrumentation Cables with rated voltage up to and including 450/750V.


                                      Cable main technical property

                                      Power cable with rated voltage up to and including 26/35kV, Control Cable and Instrumentation Cables with rated voltage up to and including 450/750V.

                                      Halogen Performance

                                          Halogen acid gas:≤5mg/g

                                          Emitted Smoke density:≥60%

                                          pHValue:≥4.3

                                          Conductivity:≤10us/mm

                                      Retardant Performance

                                          It shall pass GB/T 1 8380.1 the test on a single vertical cable under fire condition.The charred portion shall not have reached exceeding 50mm-540mm above the bottom of upper supporting shaft.

                                          The finished cables shall pass GB/T18380.3 the test on bunched cables under fire condition.The charredportion shall not have reached exceeding 2.5m above the bottom edge of the burne,and the flaming period shall not continue 1hour after stopping burning.


                                      Parameters

                                      91